ALTEON-CHEETAH-LAYER4-MIB :: slbCurNwclssCfgNetworkElementsFromIpv6Addr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALTEON-CHEETAH-LAYER4-MIBslbCurNwclssCfgNetworkElementsFromIpv6Addr

slbCurNwclssCfgNetworkElementsFromIpv6Addr

Module: ALTEON-CHEETAH-LAYER4-MIB

OID (symbolic): ALTEON-CHEETAH-LAYER4-MIB::slbCurNwclssCfgNetworkElementsFromIpv6Addr

OID (numeric): 1.3.6.1.4.1.1872.2.5.4.1.1.22.3.1.10

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: The from IPv6 address of network element. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx

What is slbCurNwclssCfgNetworkElementsFromIpv6Addr?

Reports the starting IPv6 address of an IPv6 address range for a network element in the current SLB configuration. Used when the network element is defined as an IPv6 range rather than a subnet.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.22.3.1.10
snmpwalk -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurNwclssCfgNetworkElementsFromIpv6Addr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.22.3.1.10.1
snmpget -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurNwclssCfgNetworkElementsFromIpv6Addr.1

Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CHEETAH-LAYER4-MIB::slbCurNwclssCfgNetworkElementsFromIpv6Addr OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.5aws_switchALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.5.4layer4ALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1layer4ConfigsALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1slbCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.22nwclssCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.22.3slbCurNwclssCfgNetworkElementsTableALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.22.3.1slbCurNwclssCfgNetworkElementsEntryALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.22.3.1.10slbCurNwclssCfgNetworkElementsFromIpv6AddrALTEON-CHEETAH-LAYER4-MIB