ALTEON-CHEETAH-LAYER4-MIB :: slbCurCfgVirtServSecondPartIndex

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALTEON-CHEETAH-LAYER4-MIBslbCurCfgVirtServSecondPartIndex

slbCurCfgVirtServSecondPartIndex

Module: ALTEON-CHEETAH-LAYER4-MIB

OID (symbolic): ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServSecondPartIndex

OID (numeric): 1.3.6.1.4.1.1872.2.5.4.1.1.4.12.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of the virtual server.

What is slbCurCfgVirtServSecondPartIndex?

Provides the index number identifying the virtual server in the second part of the configuration table. This is an internal table index used to reference the specific virtual server entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.4.12.1.1
snmpwalk -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServSecondPartIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.4.12.1.1.1
snmpget -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServSecondPartIndex.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> slbCurCfgVirtServSecondPartIndex.1

Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServSecondPartIndex OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.5aws_switchALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.5.4layer4ALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1layer4ConfigsALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1slbCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4virtualServerCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.12slbCurCfgVirtServicesSecondPartTableALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.12.1slbCurCfgVirtServicesSecondPartEntryALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.12.1.1slbCurCfgVirtServSecondPartIndexALTEON-CHEETAH-LAYER4-MIB