ALTEON-CHEETAH-LAYER4-MIB :: slbCurCfgVirtServPathHidePathType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALTEON-CHEETAH-LAYER4-MIBslbCurCfgVirtServPathHidePathType

slbCurCfgVirtServPathHidePathType

Module: ALTEON-CHEETAH-LAYER4-MIB

OID (symbolic): ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServPathHidePathType

OID (numeric): 1.3.6.1.4.1.1872.2.5.4.1.1.4.14.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Enter path match type [sufx|prefx|eq|none].

What is slbCurCfgVirtServPathHidePathType?

Reports the path matching type for the path-hide rule, such as suffix, prefix, exact, or none. This controls how the load balancer compares URL paths to determine which portion should be removed before forwarding the request.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.4.14.1.8
snmpwalk -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServPathHidePathType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.4.14.1.8.1
snmpget -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServPathHidePathType.1

Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CHEETAH-LAYER4-MIB::slbCurCfgVirtServPathHidePathType OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.5aws_switchALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.5.4layer4ALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1layer4ConfigsALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1slbCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4virtualServerCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.14slbCurCfgVirtServicesFourthPartTableALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.14.1slbCurCfgVirtServicesFourthPartEntryALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.4.14.1.8slbCurCfgVirtServPathHidePathTypeALTEON-CHEETAH-LAYER4-MIB