ALTEON-CHEETAH-LAYER4-MIB :: slbCurAcclCfgCachePolBrowser

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALTEON-CHEETAH-LAYER4-MIBslbCurAcclCfgCachePolBrowser

slbCurAcclCfgCachePolBrowser

Module: ALTEON-CHEETAH-LAYER4-MIB

OID (symbolic): ALTEON-CHEETAH-LAYER4-MIB::slbCurAcclCfgCachePolBrowser

OID (numeric): 1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Optimize browser cache.

What is slbCurAcclCfgCachePolBrowser?

Reports whether browser cache optimization is enabled for this caching policy. This setting controls whether the accelerator sends cache-related HTTP headers to clients to encourage or control client-side (browser) caching behavior.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5.1.10
snmpwalk -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurAcclCfgCachePolBrowser

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5.1.10.1
snmpget -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::slbCurAcclCfgCachePolBrowser.1

Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CHEETAH-LAYER4-MIB::slbCurAcclCfgCachePolBrowser OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.5aws_switchALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.5.4layer4ALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1layer4ConfigsALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1slbCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.18acclCfgALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.18.1cachingALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5slbCurAcclCfgCachePolTableALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5.1slbCurAcclCfgCachePolEntryALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.1.1.18.1.5.1.10slbCurAcclCfgCachePolBrowserALTEON-CHEETAH-LAYER4-MIB