ALTEON-CHEETAH-LAYER4-MIB :: gslbInfoVirtServerResponse

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALTEON-CHEETAH-LAYER4-MIBgslbInfoVirtServerResponse

gslbInfoVirtServerResponse

Module: ALTEON-CHEETAH-LAYER4-MIB

OID (symbolic): ALTEON-CHEETAH-LAYER4-MIB::gslbInfoVirtServerResponse

OID (numeric): 1.3.6.1.4.1.1872.2.5.4.3.6.2.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The health check response time of the virtual server or remote real server.

What is gslbInfoVirtServerResponse?

Reports the health check response time measured for a GSLB virtual server or remote real server, reflecting how quickly the server responded to the most recent probe. This metric is used to influence load balancing decisions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.3.6.2.1.7
snmpwalk -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::gslbInfoVirtServerResponse

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.5.4.3.6.2.1.7.1
snmpget -v2c -c public <target> ALTEON-CHEETAH-LAYER4-MIB::gslbInfoVirtServerResponse.1

Start monitoring Alteon (Nortel/Radware) Cheetah-based application switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALTEON-CHEETAH-LAYER4-MIB::gslbInfoVirtServerResponse OID value, configure state conditions and alerts, and monitor any Alteon (Nortel/Radware) Cheetah-based application switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.5aws_switchALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.5.4layer4ALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.3layer4InfoALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.3.6gslbInfoALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.3.6.2gslbInfoVirtServerTableALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.3.6.2.1gslbInfoVirtServerEntryALTEON-CHEETAH-LAYER4-MIB
1.3.6.1.4.1.1872.2.5.4.3.6.2.1.7gslbInfoVirtServerResponseALTEON-CHEETAH-LAYER4-MIB