All MIBs › ALC-OPT-MIB › alcPCfgAvailableMesg
alcPCfgAvailableMesg
Module: ALC-OPT-MIB
OID (symbolic): ALC-OPT-MIB::alcPCfgAvailableMesg
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.27.1.1.29
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: This specifies the text of a message that is broadcast to the ALC entity associated with this connection after a message from that terminal has been discarded due to the X.25 VC being down. This message is only sent if an Unavailable message has previously been sent to one of the terminals associated with this connection. If no message is defined, none is sent. The space character is used to blank this field. Note that this is only used on TPAD configurations.
What is alcPCfgAvailableMesg?
Read-only display string (0-62) message sent to terminals when X.25 VC recovers after being down. Example: 'System Available' notification.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.27.1.1.29 snmpwalk -v2c -c public <target> ALC-OPT-MIB::alcPCfgAvailableMesg
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.27.1.1.29.1 snmpget -v2c -c public <target> ALC-OPT-MIB::alcPCfgAvailableMesg.1
Start monitoring Motorola Codex 6500-series data/statistical multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALC-OPT-MIB::alcPCfgAvailableMesg OID value, configure state conditions and alerts, and monitor any Motorola Codex 6500-series data/statistical multiplexer (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.27 | cdx6500PPCTALCCfgTable | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.27.1 | cdx6500PPCTALCPortTable | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.27.1.1 | cdx6500PPCTALCPortEntry | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.27.1.1.29 | alcPCfgAvailableMesg | ALC-OPT-MIB |