All MIBs › ALANTEC-MIB › alPSStatus
alPSStatus
Module: ALANTEC-MIB
OID (symbolic): ALANTEC-MIB::alPSStatus
OID (numeric): 1.3.6.1.4.1.390.1.3.1.4.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The status of the power supply identified by the instance of alPSNumber.
What is alPSStatus?
Integer code indicating whether a power supply is operational, failed, or degraded. Critical for detecting hardware failures; engineers set alerts on non-operational status. Example: 1=ok, 0=failed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.390.1.3.1.4.1.2 snmpwalk -v2c -c public <target> ALANTEC-MIB::alPSStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.390.1.3.1.4.1.2.1 snmpget -v2c -c public <target> ALANTEC-MIB::alPSStatus.1
Start monitoring Alantec (Nortel) PowerHub 7000 fast Ethernet switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALANTEC-MIB::alPSStatus OID value, configure state conditions and alerts, and monitor any Alantec (Nortel) PowerHub 7000 fast Ethernet switch (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.390 | alantec | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1 | products | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1.3 | powerhub7000 | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1.3.1 | alchassis | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1.3.1.4 | alPSTable | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1.3.1.4.1 | alPSEntry | ALANTEC-MIB |
| 1.3.6.1.4.1.390.1.3.1.4.1.2 | alPSStatus | ALANTEC-MIB |