ADVANTECH-COMMON-MIB :: sysFirstBootTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ADVANTECH-COMMON-MIB › sysFirstBootTime

sysFirstBootTime

Module: ADVANTECH-COMMON-MIB

OID (symbolic): ADVANTECH-COMMON-MIB::sysFirstBootTime

OID (numeric): 1.3.6.1.4.1.10297.100.1.6

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: The first boot time since the entity/device was started
        it will be reset if the device cleaned all files and registry
        with clean boot.
        
A date-time specification.
        field  octets  contents                  range
        -----  ------  --------                  -----
          1      1-2   year                      0..65536
          2       3    month                     1..12
          3       4    day                       1..31
          4       5    hour                      0..23
          5       6    minutes                   0..59
          6       7    seconds                   0..60
                       (use 60 for leap-second)
          7       8    deci-seconds              0..9
          8       9    direction from UTC        '+' / '-'
          9      10    hours from UTC            0..11
         10      11    minutes from UTC          0..59
        If this information is not known, then this
        variable shall have the value corresponding to
        January 1, year 0000, 00:00:00.0, which is encoded
        as (hex)'00 00 01 01 00 00 00 00'.

What is sysFirstBootTime?

This timestamp marks when the device first booted after manufacturing or a clean factory reset. Resets only if the device is cleaned of all files. Helps track device age.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.100.1.6
snmpwalk -v2c -c public <target> ADVANTECH-COMMON-MIB::sysFirstBootTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.100.1.6.1
snmpget -v2c -c public <target> ADVANTECH-COMMON-MIB::sysFirstBootTime.1

Start monitoring Advantech industrial networking equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-COMMON-MIB::sysFirstBootTime OID value, configure state conditions and alerts, and monitor any Advantech industrial networking equipment from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-COMMON-MIB
1.3.6.1.4.1.10297.100advantechCommonMIBADVANTECH-COMMON-MIB
1.3.6.1.4.1.10297.100.1atSystemADVANTECH-COMMON-MIB
1.3.6.1.4.1.10297.100.1.6sysFirstBootTimeADVANTECH-COMMON-MIB