ADVA-FSPR7-DEF-MIB :: physicalPortDefTimModeOduTcmC

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-DEF-MIBphysicalPortDefTimModeOduTcmC

physicalPortDefTimModeOduTcmC

Module: ADVA-FSPR7-DEF-MIB

OID (symbolic): ADVA-FSPR7-DEF-MIB::physicalPortDefTimModeOduTcmC

OID (numeric): 1.3.6.1.4.1.2544.1.11.10.3.4.1.1.72

Node type: OBJECT-TYPE

Type: TimMode

Access: read-only

Description: Detection of TIM-TCMC Condition can be configured

What is physicalPortDefTimModeOduTcmC?

This OID controls whether the port can detect a Trace Identifier Mismatch condition on the ODU TCM-C level of the optical signal. Network engineers use this to monitor transmission quality on optical interfaces and detect when the path identifier doesn't match expectations. Setting this to enabled means the equipment will alarm if the incoming TCM-C trace doesn't match the expected value, helping catch cross-connects or misroutes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.10.3.4.1.1.72
snmpwalk -v2c -c public <target> ADVA-FSPR7-DEF-MIB::physicalPortDefTimModeOduTcmC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.10.3.4.1.1.72.1
snmpget -v2c -c public <target> ADVA-FSPR7-DEF-MIB::physicalPortDefTimModeOduTcmC.1

Start monitoring ADVA FSP 3000 R7 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-DEF-MIB::physicalPortDefTimModeOduTcmC OID value, configure state conditions and alerts, and monitor any ADVA FSP 3000 R7 optical transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.10advaFspR7DefADVA-FSPR7-DEF-MIB
1.3.6.1.4.1.2544.1.11.10.3managementDefADVA-FSPR7-DEF-MIB
1.3.6.1.4.1.2544.1.11.10.3.4facilityMgmtDefADVA-FSPR7-DEF-MIB
1.3.6.1.4.1.2544.1.11.10.3.4.1physicalPortDefTableADVA-FSPR7-DEF-MIB
1.3.6.1.4.1.2544.1.11.10.3.4.1.1physicalPortDefEntryADVA-FSPR7-DEF-MIB
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.72physicalPortDefTimModeOduTcmCADVA-FSPR7-DEF-MIB