Description: ODU Tandem Connection B Background Block Errors 1 Day Threshold
What is tcmBFacilityDataThresholdCapOduTcmBBbeHighThres1day?
This OID stores the background block errors threshold for TCM B over 24 hours (Counter64). Engineers use daily BBE counts to detect gradual fiber degradation or equipment aging that will eventually require maintenance. For example, setting this to 10000 means the system triggers an alert if 10000 or more blocks accumulate errors over a 24-hour period.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.5.1.6 snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::tcmBFacilityDataThresholdCapOduTcmBBbeHighThres1day
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.5.1.6.1 snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::tcmBFacilityDataThresholdCapOduTcmBBbeHighThres1day.1
Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::tcmBFacilityDataThresholdCapOduTcmBBbeHighThres1day OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.9 | advaFspR7Cap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6 | performanceCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12 | pmFacilityCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1 | pmFacilityDataCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1 | pmFacilityDataThresholdCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.5 | tcmBFacilityDataThresholdCapTable | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.5.1 | tcmBFacilityDataThresholdCapEntry | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.5.1.6 | tcmBFacilityDataThresholdCapOduTcmBBbeHighThres1day | ADVA-FSPR7-CAP-MIB |