Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::sFacilityDataThresholdCapSEFSHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19.1.5

Node type: OBJECT-TYPE

Type: FspR7Unsigned32Caps

Access: read-only

Description: Section Severely Errored Frame Seconds 15 Minute Threshold

What is sFacilityDataThresholdCapSEFSHighThres15min?

This OID indicates the maximum severely errored frame seconds threshold that can be monitored over 15 minutes on a section facility. Frame errors mean entire optical frames are corrupted or lost, which is more serious than individual bit errors and requires immediate investigation. A threshold value of 25 would mean alerting when the section has 25 or more severely errored frame seconds in a 15-minute span.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::sFacilityDataThresholdCapSEFSHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::sFacilityDataThresholdCapSEFSHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::sFacilityDataThresholdCapSEFSHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19sFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19.1sFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.19.1.5sFacilityDataThresholdCapSEFSHighThres15minADVA-FSPR7-CAP-MIB