ADVA-FSPR7-CAP-MIB :: otuFecFacilityDataThresholdCapSESHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBotuFecFacilityDataThresholdCapSESHighThres15min

otuFecFacilityDataThresholdCapSESHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapSESHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.3

Node type: OBJECT-TYPE

Type: FspR7Unsigned32Caps

Access: read-only

Description: OTU FEC Severely Errored Seconds 15 Minute Threshold

What is otuFecFacilityDataThresholdCapSESHighThres15min?

This OID stores the maximum severely errored seconds on an OTU FEC layer during a 15-minute period. Severely errored seconds at the FEC level indicate the optical signal is degraded enough that even error correction is struggling. A threshold of 10 severely errored seconds on FEC means the system alerts immediately if the signal quality drops significantly in 15 minutes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapSESHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapSESHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapSESHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11otuFecFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1otuFecFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.3otuFecFacilityDataThresholdCapSESHighThres15minADVA-FSPR7-CAP-MIB