ADVA-FSPR7-CAP-MIB :: otuFecFacilityDataThresholdCapESHighThres1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBotuFecFacilityDataThresholdCapESHighThres1day

otuFecFacilityDataThresholdCapESHighThres1day

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.2

Node type: OBJECT-TYPE

Type: FspR7Unsigned32Caps

Access: read-only

Description: OTU FEC Errored Seconds Day Threshold

What is otuFecFacilityDataThresholdCapESHighThres1day?

This OID stores the maximum FEC errored seconds on an OTU permitted during a full 24-hour day. Engineers use this daily metric to monitor whether the FEC decoder is working overtime and correcting an increasing volume of errors. A daily threshold of 10,000 errored seconds in the FEC layer suggests the physical signal quality is degrading and may need optical power adjustment or amplifier maintenance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres1day.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres1day OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11otuFecFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1otuFecFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.2otuFecFacilityDataThresholdCapESHighThres1dayADVA-FSPR7-CAP-MIB