All MIBs › ADVA-FSPR7-CAP-MIB › otuFecFacilityDataThresholdCapESHighThres15min
otuFecFacilityDataThresholdCapESHighThres15min
Module: ADVA-FSPR7-CAP-MIB
OID (symbolic): ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres15min
OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.1
Node type: OBJECT-TYPE
Type: FspR7Unsigned32Caps
Access: read-only
Description: OTU FEC Errored Seconds 15 Minute Threshold
What is otuFecFacilityDataThresholdCapESHighThres15min?
This OID stores the maximum errored seconds allowed on an OTU FEC (Forward Error Correction) decoder during a 15-minute interval. The FEC layer detects errors that the physical layer introduces, so this threshold monitors the health of error-correction logic itself. A typical threshold of 100 means alarms trigger if the FEC decoder encounters correctable errors for more than 100 seconds in 15 minutes.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.1 snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres15min
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.1.1 snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres15min.1
Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapESHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.9 | advaFspR7Cap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6 | performanceCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12 | pmFacilityCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1 | pmFacilityDataCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1 | pmFacilityDataThresholdCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11 | otuFecFacilityDataThresholdCapTable | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1 | otuFecFacilityDataThresholdCapEntry | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.1 | otuFecFacilityDataThresholdCapESHighThres15min | ADVA-FSPR7-CAP-MIB |