ADVA-FSPR7-CAP-MIB :: otuFecFacilityDataThresholdCapBERCErrHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBotuFecFacilityDataThresholdCapBERCErrHighThres15min

otuFecFacilityDataThresholdCapBERCErrHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapBERCErrHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.9

Node type: OBJECT-TYPE

Type: Counter64StringCaps

Access: read-only

Description: Bit Error Rate before FEC 15 Minute Threshold

What is otuFecFacilityDataThresholdCapBERCErrHighThres15min?

This OID stores the high alarm threshold for bit error rate (BER) measured before forward error correction is applied, tracked over 15-minute intervals. Network engineers configure this threshold to trigger alerts when the signal quality drops too much, indicating potential fiber degradation or equipment issues. A typical threshold might be set to 1e-9 (one error per billion bits), and if the 15-minute BER exceeds this value, an alarm fires.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.9
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapBERCErrHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.9.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapBERCErrHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::otuFecFacilityDataThresholdCapBERCErrHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11otuFecFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1otuFecFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.11.1.9otuFecFacilityDataThresholdCapBERCErrHighThres15minADVA-FSPR7-CAP-MIB