ADVA-FSPR7-CAP-MIB :: oduFacilityDataThresholdCapUASHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBoduFacilityDataThresholdCapUASHighThres15min

oduFacilityDataThresholdCapUASHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapUASHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.7

Node type: OBJECT-TYPE

Type: FspR7Unsigned32Caps

Access: read-only

Description: ODU Unavailable Seconds 15 Minute Threshold

What is oduFacilityDataThresholdCapUASHighThres15min?

This OID records the maximum number of unavailable seconds (UAS, when the ODU signal is completely lost or unusable) permitted in a 15-minute window. When this threshold is exceeded, it triggers an alarm that indicates the link has had a total outage or the signal dropped below the minimum detectable level. A typical limit of 0 UAS means any loss of signal in 15 minutes is a critical event requiring immediate troubleshooting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.7
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapUASHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.7.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapUASHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapUASHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1oduFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1oduFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.7oduFacilityDataThresholdCapUASHighThres15minADVA-FSPR7-CAP-MIB