ADVA-FSPR7-CAP-MIB :: oduFacilityDataThresholdCapESHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBoduFacilityDataThresholdCapESHighThres15min

oduFacilityDataThresholdCapESHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapESHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.1

Node type: OBJECT-TYPE

Type: FspR7Unsigned32Caps

Access: read-only

Description: ODU Errored Seconds 15 Minute Threshold

What is oduFacilityDataThresholdCapESHighThres15min?

This OID stores the maximum number of errored seconds (ES) allowed in a 15-minute window for an ODU (Optical Data Unit) before an alarm is raised. Network operators set and monitor this threshold to detect degrading fiber quality or equipment health in near-real-time. A typical value might be 5 seconds, meaning if more than 5 seconds of bit errors occur in any 15-minute interval, the system triggers an alert.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.1
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapESHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.1.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapESHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapESHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1oduFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1oduFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.1oduFacilityDataThresholdCapESHighThres15minADVA-FSPR7-CAP-MIB