ADVA-FSPR7-CAP-MIB :: oduFacilityDataThresholdCapBbeHighThres1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBoduFacilityDataThresholdCapBbeHighThres1day

oduFacilityDataThresholdCapBbeHighThres1day

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.6

Node type: OBJECT-TYPE

Type: Counter64StringCaps

Access: read-only

Description: ODU Background Block Errors 1 Day Threshold

What is oduFacilityDataThresholdCapBbeHighThres1day?

This OID specifies the daily ceiling for background block errors (BBE) on an ODU, expressed as a 64-bit counter that resets every 24 hours. Operations teams use this to monitor cumulative data quality and predict when equipment will fail or degrade beyond service-level agreement limits. A daily BBE threshold of 1 million errors might be normal for aging equipment in a noisy environment, but trending upward signals imminent maintenance need.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres1day.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres1day OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1oduFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1oduFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.6oduFacilityDataThresholdCapBbeHighThres1dayADVA-FSPR7-CAP-MIB