ADVA-FSPR7-CAP-MIB :: oduFacilityDataThresholdCapBbeHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBoduFacilityDataThresholdCapBbeHighThres15min

oduFacilityDataThresholdCapBbeHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.5

Node type: OBJECT-TYPE

Type: Counter64StringCaps

Access: read-only

Description: ODU Background Block Errors 15 Minute Threshold

What is oduFacilityDataThresholdCapBbeHighThres15min?

This OID holds the maximum count of background block errors (BBE, correctable bit errors detected in ODU frames) during any 15-minute window. Network administrators track this metric to catch fiber or receiver degradation before it becomes severe enough to cause data loss or alarms. For example, a BBE threshold of 100,000 errors per 15 minutes might indicate the link is still healthy, but sustained values near the limit suggest aging optics.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::oduFacilityDataThresholdCapBbeHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1oduFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1oduFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.1.1.5oduFacilityDataThresholdCapBbeHighThres15minADVA-FSPR7-CAP-MIB