ADVA-FSPR7-CAP-MIB :: fecFacilityDataThresholdCapCEHighThres15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBfecFacilityDataThresholdCapCEHighThres15min

fecFacilityDataThresholdCapCEHighThres15min

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::fecFacilityDataThresholdCapCEHighThres15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13.1.1

Node type: OBJECT-TYPE

Type: Counter64StringCaps

Access: read-only

Description: FEC Corrected Errors 15 Minute Threshold

What is fecFacilityDataThresholdCapCEHighThres15min?

This OID counts the number of errors that the FEC (Forward Error Correction) system successfully corrected over a 15-minute period. Engineers monitor this metric to watch for increasing error rates even though they are being fixed, as a rising trend suggests the optical signal is degrading. For example, if this threshold is set to 10,000 corrected errors per 15 minutes and exceeded, it warns that the line is approaching its error correction limit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13.1.1
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::fecFacilityDataThresholdCapCEHighThres15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13.1.1.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::fecFacilityDataThresholdCapCEHighThres15min.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::fecFacilityDataThresholdCapCEHighThres15min OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1pmFacilityDataCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1pmFacilityDataThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13fecFacilityDataThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13.1fecFacilityDataThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.1.1.13.1.1fecFacilityDataThresholdCapCEHighThres15minADVA-FSPR7-CAP-MIB