ADVA-FSPR7-CAP-MIB :: facilityPhysThresholdCapDifferentialGroupDelayHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBfacilityPhysThresholdCapDifferentialGroupDelayHigh

facilityPhysThresholdCapDifferentialGroupDelayHigh

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapDifferentialGroupDelayHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.17

Node type: OBJECT-TYPE

Type: FspR7Integer32Caps

Access: read-only

Description: Differential Group Delay High TH

What is facilityPhysThresholdCapDifferentialGroupDelayHigh?

This OID stores the maximum high threshold for differential group delay (DGD) in the optical signal, measured in picoseconds per nanometer (ps/nm). Differential group delay causes pulse broadening and bit errors on high-speed links, especially coherent 100G/400G interfaces, requiring careful monitoring. A value of 50 ps/nm means you can set an alarm when DGD exceeds 50 ps/nm, triggering service quality alerts before data errors occur.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.17
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapDifferentialGroupDelayHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.17.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapDifferentialGroupDelayHigh.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapDifferentialGroupDelayHigh OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2pmFacilityPhysicalCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2pmFacilityPhysThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1facilityPhysThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1facilityPhysThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.17facilityPhysThresholdCapDifferentialGroupDelayHighADVA-FSPR7-CAP-MIB