ADVA-FSPR7-CAP-MIB :: facilityPhysThresholdCapChromaticDispersionLow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBfacilityPhysThresholdCapChromaticDispersionLow

facilityPhysThresholdCapChromaticDispersionLow

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapChromaticDispersionLow

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.10

Node type: OBJECT-TYPE

Type: FspR7Integer32Caps

Access: read-only

Description: Chromatic Dispersion Compensation Low Threshold

What is facilityPhysThresholdCapChromaticDispersionLow?

This OID stores the minimum low threshold for chromatic dispersion compensation that the equipment can monitor and apply. Engineers set low thresholds to warn when dispersion compensation drops below optimal levels on long-haul links, indicating potential filter misalignment or equipment degradation. A value of 100 ps/nm means alerts can trigger when compensation capability falls below this level, signaling service quality risk.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.10
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapChromaticDispersionLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.10.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapChromaticDispersionLow.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::facilityPhysThresholdCapChromaticDispersionLow OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6performanceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12pmFacilityCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2pmFacilityPhysicalCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2pmFacilityPhysThresholdCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1facilityPhysThresholdCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1facilityPhysThresholdCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.6.12.2.2.1.1.10facilityPhysThresholdCapChromaticDispersionLowADVA-FSPR7-CAP-MIB