All MIBs › ADVA-FSPR7-CAP-MIB › changePhysicalPortServiceCapTraceTransmitSapiOduTcmC
changePhysicalPortServiceCapTraceTransmitSapiOduTcmC
Module: ADVA-FSPR7-CAP-MIB
OID (symbolic): ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC
OID (numeric): 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: The transmitted SAPI part of the TCMC trace (15 character)
What is changePhysicalPortServiceCapTraceTransmitSapiOduTcmC?
This OID displays the 15-character SAPI (Service Access Point Identifier) label that is transmitted within the TCMC trace header on an optical port. Network engineers use this to identify and track service instances traveling through the optical network for monitoring and troubleshooting. For example, a value of "SERVICE_A_PORT_1" would indicate that traffic from Service A on Port 1 is being transmitted with this identifier.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79 snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79.1 snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC.1
Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.9 | advaFspR7Cap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.7 | featureSpecificCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.7.5 | changeServiceCap | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.7.5.1 | changePhysicalPortServiceCapTable | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.7.5.1.1 | changePhysicalPortServiceCapEntry | ADVA-FSPR7-CAP-MIB |
| 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79 | changePhysicalPortServiceCapTraceTransmitSapiOduTcmC | ADVA-FSPR7-CAP-MIB |