ADVA-FSPR7-CAP-MIB :: changePhysicalPortServiceCapTraceTransmitSapiOduTcmC

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBchangePhysicalPortServiceCapTraceTransmitSapiOduTcmC

changePhysicalPortServiceCapTraceTransmitSapiOduTcmC

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The transmitted SAPI part of the TCMC trace (15 character)

What is changePhysicalPortServiceCapTraceTransmitSapiOduTcmC?

This OID displays the 15-character SAPI (Service Access Point Identifier) label that is transmitted within the TCMC trace header on an optical port. Network engineers use this to identify and track service instances traveling through the optical network for monitoring and troubleshooting. For example, a value of "SERVICE_A_PORT_1" would indicate that traffic from Service A on Port 1 is being transmitted with this identifier.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceTransmitSapiOduTcmC OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7featureSpecificCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5changeServiceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1changePhysicalPortServiceCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1changePhysicalPortServiceCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1.79changePhysicalPortServiceCapTraceTransmitSapiOduTcmCADVA-FSPR7-CAP-MIB