ADVA-FSPR7-CAP-MIB :: changePhysicalPortServiceCapTraceExpectedOdu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBchangePhysicalPortServiceCapTraceExpectedOdu

changePhysicalPortServiceCapTraceExpectedOdu

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceExpectedOdu

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.66

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Expected SAPI part of the ODU trace (15 character). NULL TRACE implies that no trace comparison is made.

What is changePhysicalPortServiceCapTraceExpectedOdu?

This stores the expected SAPI portion of the ODU (Optical Data Unit) trace that should be received, with 15 character limit and NULL disabling validation. Engineers configure this to ensure incoming ODU signals match the anticipated path, detecting miswiring or misrouting. Example: 'ODUSRC-MAIN-01' would validate that ODU traffic originates from the main source.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.66
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceExpectedOdu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.66.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceExpectedOdu.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapTraceExpectedOdu OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7featureSpecificCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5changeServiceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1changePhysicalPortServiceCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1changePhysicalPortServiceCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1.66changePhysicalPortServiceCapTraceExpectedOduADVA-FSPR7-CAP-MIB