ADVA-FSPR7-CAP-MIB :: changePhysicalPortServiceCapAlsMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-CAP-MIBchangePhysicalPortServiceCapAlsMode

changePhysicalPortServiceCapAlsMode

Module: ADVA-FSPR7-CAP-MIB

OID (symbolic): ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapAlsMode

OID (numeric): 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.5

Node type: OBJECT-TYPE

Type: FspR7AlsModeCaps

Access: read-only

Description: Determines the reaction in backward direction in response to a LOS on the same Interface: on a Network Interface connected to the DWDM this is a matter of laser safety

What is changePhysicalPortServiceCapAlsMode?

This determines how the port reacts when it detects loss of signal (LOS) in the backward direction, with special attention to laser safety on DWDM network interfaces. You'd configure this to prevent dangerous laser emissions or prevent cascading failures when upstream links fail. For example, setting this to 'shutDown' turns off the laser if signal is lost on the incoming side.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapAlsMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.9.7.5.1.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapAlsMode.1

Start monitoring ADVA FSP R7 optical transport network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CAP-MIB::changePhysicalPortServiceCapAlsMode OID value, configure state conditions and alerts, and monitor any ADVA FSP R7 optical transport network elements from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.9advaFspR7CapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7featureSpecificCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5changeServiceCapADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1changePhysicalPortServiceCapTableADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1changePhysicalPortServiceCapEntryADVA-FSPR7-CAP-MIB
1.3.6.1.4.1.2544.1.11.9.7.5.1.1.5changePhysicalPortServiceCapAlsModeADVA-FSPR7-CAP-MIB