All MIBs › ADTRAN-DS1-MIB › adDS1AlarmEnable
adDS1AlarmEnable
Module: ADTRAN-DS1-MIB
OID (symbolic): ADTRAN-DS1-MIB::adDS1AlarmEnable
OID (numeric): 1.3.6.1.4.1.664.2.3.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Enables or disables the generation of DS1 Alarm Traps for Line Status event changes.
What is adDS1AlarmEnable?
This setting turns on (value 2) or off (value 1) automatic trap generation when DS1 line status changes. When enabled, the device sends SNMP alerts when alarms occur. When disabled, status changes are logged but no alerts fire.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.664.2.3.1.1.2 snmpwalk -v2c -c public <target> ADTRAN-DS1-MIB::adDS1AlarmEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.664.2.3.1.1.2.1 snmpget -v2c -c public <target> ADTRAN-DS1-MIB::adDS1AlarmEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.664.2.3.1.1.2.1 i <value>
Start monitoring ADTRAN CSU/DSUs and routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADTRAN-DS1-MIB::adDS1AlarmEnable OID value, configure state conditions and alerts, and monitor any ADTRAN CSU/DSUs and routers from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.664 | adtran | ADTRAN-ACTDAX-MIB |
| 1.3.6.1.4.1.664.2 | adMgmt | ADTRAN-ACTDAX-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.664.2.3 | adDS1mg | ADTRAN-DS1-MIB |
| 1.3.6.1.4.1.664.2.3.1 | adDS1AlarmTable | ADTRAN-DS1-MIB |
| 1.3.6.1.4.1.664.2.3.1.1 | adDS1AlarmEntry | ADTRAN-DS1-MIB |
| 1.3.6.1.4.1.664.2.3.1.1.2 | adDS1AlarmEnable | ADTRAN-DS1-MIB |