Access: read-write
Description: Enable or disable vadc user backdoor access.
What is vADCUserNewCfgBackdoor?
This OID reports a boolean flag indicating whether backdoor access is enabled in a pending new user configuration. Pre-deployment security audits should confirm this value is disabled (0) to prevent accidental enablement of unauthorized access paths. Example value: 0 (disabled, recommended) or 1 (enabled)
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.8 snmpwalk -v2c -c public <target> ADMIN-ALTEON-AC-vADC-MIB::vADCUserNewCfgBackdoor
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.8.1 snmpget -v2c -c public <target> ADMIN-ALTEON-AC-vADC-MIB::vADCUserNewCfgBackdoor.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.8.1 i <value>
Start monitoring Radware Alteon ADCs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADMIN-ALTEON-AC-vADC-MIB::vADCUserNewCfgBackdoor OID value, configure state conditions and alerts, and monitor any Radware Alteon ADCs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1872 | alteon | ALTEON-PRIVATE-MIBS |
| 1.3.6.1.4.1.1872.2 | private_mibs | ALTEON-PRIVATE-MIBS |
| 1.3.6.1.4.1.1872.2.6 | virt_admin | ALTEON-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1872.2.6.1 | adminvADC | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1 | adminvADCConfigs | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1 | vADCConfig | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1.9 | vADCAccessUser | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1.9.1 | vADCAccessUid | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2 | vADCUserNewCfgTable | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1 | vADCUserNewCfgTableEntry | ADMIN-ALTEON-AC-vADC-MIB |
| 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.8 | vADCUserNewCfgBackdoor | ADMIN-ALTEON-AC-vADC-MIB |