ADMIN-ALTEON-AC-vADC-MIB :: vADCCurCfgSysPeerIpv6Addr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADMIN-ALTEON-AC-vADC-MIBvADCCurCfgSysPeerIpv6Addr

vADCCurCfgSysPeerIpv6Addr

Module: ADMIN-ALTEON-AC-vADC-MIB

OID (symbolic): ADMIN-ALTEON-AC-vADC-MIB::vADCCurCfgSysPeerIpv6Addr

OID (numeric): 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.24

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: The peer IPV6 Address of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx

What is vADCCurCfgSysPeerIpv6Addr?

Reports a 128-bit IPv6 address value representing the IPv6 address of the peer vADC system in a high-availability setup. From a network monitoring standpoint, this OID identifies the redundant peer device's IPv6 address for synchronization and failover purposes. A concrete example is 2001:db8::2, representing the peer vADC's IPv6 address.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.24
snmpwalk -v2c -c public <target> ADMIN-ALTEON-AC-vADC-MIB::vADCCurCfgSysPeerIpv6Addr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.24.1
snmpget -v2c -c public <target> ADMIN-ALTEON-AC-vADC-MIB::vADCCurCfgSysPeerIpv6Addr.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> vADCCurCfgSysPeerIpv6Addr.1

Start monitoring Radware Alteon ADCs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADMIN-ALTEON-AC-vADC-MIB::vADCCurCfgSysPeerIpv6Addr OID value, configure state conditions and alerts, and monitor any Radware Alteon ADCs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1872alteonALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2private_mibsALTEON-PRIVATE-MIBS
1.3.6.1.4.1.1872.2.6virt_adminALTEON-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1872.2.6.1adminvADCADMIN-ALTEON-AC-vADC-MIB
1.3.6.1.4.1.1872.2.6.1.1adminvADCConfigsADMIN-ALTEON-AC-vADC-MIB
1.3.6.1.4.1.1872.2.6.1.1.1vADCConfigADMIN-ALTEON-AC-vADC-MIB
1.3.6.1.4.1.1872.2.6.1.1.1.5vADCCurCfgSysTableADMIN-ALTEON-AC-vADC-MIB
1.3.6.1.4.1.1872.2.6.1.1.1.5.1vADCCurCfgSysTableEntryADMIN-ALTEON-AC-vADC-MIB
1.3.6.1.4.1.1872.2.6.1.1.1.5.1.24vADCCurCfgSysPeerIpv6AddrADMIN-ALTEON-AC-vADC-MIB