All MIBs › ADAPTEC-UNIVERSAL-STORAGE-MIB › ausChannelControllerId
ausChannelControllerId
Module: ADAPTEC-UNIVERSAL-STORAGE-MIB
OID (symbolic): ADAPTEC-UNIVERSAL-STORAGE-MIB::ausChannelControllerId
OID (numeric): 1.3.6.1.4.1.795.14.1.300.1.1.7
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Controller ID number used on this channel. Meaning is dependent on channelType. For example, SCSI channels would report controller SCSI ID in this field. The field is a string to allow for a wide range of addressing schemes.
What is ausChannelControllerId?
This OID stores a text identifier or product code for the controller hardware that owns this channel. A network engineer uses this to identify the specific controller model and correlate it with hardware documentation or known firmware issues. For example, ausChannelControllerId might be '12G-2 SAS RAID' for an Adaptec 12G SAS RAID controller.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.795.14.1.300.1.1.7 snmpwalk -v2c -c public <target> ADAPTEC-UNIVERSAL-STORAGE-MIB::ausChannelControllerId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.795.14.1.300.1.1.7.1 snmpget -v2c -c public <target> ADAPTEC-UNIVERSAL-STORAGE-MIB::ausChannelControllerId.1
Start monitoring Adaptec RAID storage controllers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADAPTEC-UNIVERSAL-STORAGE-MIB::ausChannelControllerId OID value, configure state conditions and alerts, and monitor any Adaptec RAID storage controllers from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.795 | adaptec | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14 | universalStorage | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14.1 | ausMIB | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14.1.300 | ausChannel | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14.1.300.1 | ausChannelTable | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14.1.300.1.1 | ausChannelEntry | ADAPTEC-UNIVERSAL-STORAGE-MIB |
| 1.3.6.1.4.1.795.14.1.300.1.1.7 | ausChannelControllerId | ADAPTEC-UNIVERSAL-STORAGE-MIB |