All MIBs › ACS8000-MIB › acsPowerMgmtPDUTableTemperature1Value
acsPowerMgmtPDUTableTemperature1Value
Module: ACS8000-MIB
OID (symbolic): ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Value
OID (numeric): 1.3.6.1.4.1.10418.26.2.5.3.1.17
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
What is acsPowerMgmtPDUTableTemperature1Value?
This OID reports the current temperature measured by sensor 1 in the PDU, stored as the actual temperature in Celsius multiplied by 10 (range 5-999 equals 0.5-99.9°C). Operators monitor this value to ensure the power unit stays within safe operating temperature ranges and to detect cooling system failures. A value of 245 means the current temperature is 24.5 degrees Celsius.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.3.1.17 snmpwalk -v2c -c public <target> ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Value
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.3.1.17.1 snmpget -v2c -c public <target> ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Value.1
Start monitoring Vertiv (Avocent) ACS 8000 console servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Value OID value, configure state conditions and alerts, and monitor any Vertiv (Avocent) ACS 8000 console servers from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.10418.26 | acs | ACS8000-MIB |
| 1.3.6.1.4.1.10418.26.2 | acsManagement | ACS8000-MIB |
| 1.3.6.1.4.1.10418.26.2.5 | acsPowerMgmt | ACS8000-MIB |
| 1.3.6.1.4.1.10418.26.2.5.3 | acsPowerMgmtPDUTable | ACS8000-MIB |
| 1.3.6.1.4.1.10418.26.2.5.3.1 | acsPowerMgmtPDUTableEntry | ACS8000-MIB |
| 1.3.6.1.4.1.10418.26.2.5.3.1.17 | acsPowerMgmtPDUTableTemperature1Value | ACS8000-MIB |