ACS8000-MIB :: acsPowerMgmtPDUTableTemperature1Max

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACS8000-MIBacsPowerMgmtPDUTableTemperature1Max

acsPowerMgmtPDUTableTemperature1Max

Module: ACS8000-MIB

OID (symbolic): ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Max

OID (numeric): 1.3.6.1.4.1.10418.26.2.5.3.1.18

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.

What is acsPowerMgmtPDUTableTemperature1Max?

This OID tracks and stores the maximum temperature ever recorded by sensor 1, using the same format as the current value (multiplied by 10). Engineers review this historical maximum to understand peak thermal stress on the equipment and can reset it to establish new baseline monitoring periods. A value of 520 indicates the highest temperature recorded was 52.0 degrees Celsius.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.3.1.18
snmpwalk -v2c -c public <target> ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Max

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.3.1.18.1
snmpget -v2c -c public <target> ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Max.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10418.26.2.5.3.1.18.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> acsPowerMgmtPDUTableTemperature1Max.1

Start monitoring Vertiv (Avocent) ACS 8000 console servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACS8000-MIB::acsPowerMgmtPDUTableTemperature1Max OID value, configure state conditions and alerts, and monitor any Vertiv (Avocent) ACS 8000 console servers from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10418.26acsACS8000-MIB
1.3.6.1.4.1.10418.26.2acsManagementACS8000-MIB
1.3.6.1.4.1.10418.26.2.5acsPowerMgmtACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.3acsPowerMgmtPDUTableACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.3.1acsPowerMgmtPDUTableEntryACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.3.1.18acsPowerMgmtPDUTableTemperature1MaxACS8000-MIB