ACS8000-MIB :: acsPowerMgmtOutletsTablePowerControl

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACS8000-MIBacsPowerMgmtOutletsTablePowerControl

acsPowerMgmtOutletsTablePowerControl

Module: ACS8000-MIB

OID (symbolic): ACS8000-MIB::acsPowerMgmtOutletsTablePowerControl

OID (numeric): 1.3.6.1.4.1.10418.26.2.5.5.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs

What is acsPowerMgmtOutletsTablePowerControl?

This read-write OID allows remote control of an outlet's power state with options to turn on, off, cycle, lock, or unlock the outlet (values 2-6). An engineer uses this for remote reboot of hung devices, emergency power shutdowns, and controlled maintenance without physical access to the data center. For example, setting this to 'powerCycle(4)' remotely reboots a server by cutting power and restoring it automatically.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.5.1.6
snmpwalk -v2c -c public <target> ACS8000-MIB::acsPowerMgmtOutletsTablePowerControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10418.26.2.5.5.1.6.1
snmpget -v2c -c public <target> ACS8000-MIB::acsPowerMgmtOutletsTablePowerControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10418.26.2.5.5.1.6.1 i <value>

Start monitoring Vertiv (Avocent) ACS 8000 console servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACS8000-MIB::acsPowerMgmtOutletsTablePowerControl OID value, configure state conditions and alerts, and monitor any Vertiv (Avocent) ACS 8000 console servers from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10418.26acsACS8000-MIB
1.3.6.1.4.1.10418.26.2acsManagementACS8000-MIB
1.3.6.1.4.1.10418.26.2.5acsPowerMgmtACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.5acsPowerMgmtOutletsTableACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.5.1acsPowerMgmtOutletsTableEntryACS8000-MIB
1.3.6.1.4.1.10418.26.2.5.5.1.6acsPowerMgmtOutletsTablePowerControlACS8000-MIB