ACD-REGULATOR-MIB :: acdRegulatorStatsAcceptOctets

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACD-REGULATOR-MIBacdRegulatorStatsAcceptOctets

acdRegulatorStatsAcceptOctets

Module: ACD-REGULATOR-MIB

OID (symbolic): ACD-REGULATOR-MIB::acdRegulatorStatsAcceptOctets

OID (numeric): 1.3.6.1.4.1.22420.2.6.2.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of octets received by this regulator. This is a 32 bits counter. Combined with acdRegulatorStatsAcceptOverflowOctets, it provides the equivalent of the 64 bits counter acdRegulatorStatsAcceptHCOctets.

What is acdRegulatorStatsAcceptOctets?

This 32-bit counter tracks the total number of bytes (octets) the regulator has accepted and passed through. Network engineers monitor this metric to measure throughput and detect changes in traffic patterns. For example, a value of 1000000000 indicates the regulator has transmitted 1 billion bytes since the counter last reset.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.2.6.2.1.2
snmpwalk -v2c -c public <target> ACD-REGULATOR-MIB::acdRegulatorStatsAcceptOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.2.6.2.1.2.1
snmpget -v2c -c public <target> ACD-REGULATOR-MIB::acdRegulatorStatsAcceptOctets.1

Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-REGULATOR-MIB::acdRegulatorStatsAcceptOctets OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.

How to Use in IPNetwork Monitor

Select an Accedian MetroNID device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type acdRegulatorStatsAcceptOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of octets received by this regulator. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in Octets), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22420accedianMIBACCEDIAN-SMI
1.3.6.1.4.1.22420.2acdMibsACCEDIAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.22420.2.6acdRegulatorACD-REGULATOR-MIB
1.3.6.1.4.1.22420.2.6.2acdRegulatorStatsTableACD-REGULATOR-MIB
1.3.6.1.4.1.22420.2.6.2.1acdRegulatorStatsEntryACD-REGULATOR-MIB
1.3.6.1.4.1.22420.2.6.2.1.2acdRegulatorStatsAcceptOctetsACD-REGULATOR-MIB