All MIBs › ACD-DESC-MIB › acdDescTsFirstThres
acdDescTsFirstThres
Module: ACD-DESC-MIB
OID (symbolic): ACD-DESC-MIB::acdDescTsFirstThres
OID (numeric): 1.3.6.1.4.1.22420.1.1.12.1.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Temperature value in Celsius to declare this threshold crossed.
What is acdDescTsFirstThres?
This OID stores the first temperature threshold value in Celsius as an integer that triggers an alert when crossed. You set this to establish a warning level for elevated temperatures before the device becomes too hot. For example, a value of "50" means the device will warn you if temperature exceeds 50 degrees Celsius.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.1.1.12.1.3 snmpwalk -v2c -c public <target> ACD-DESC-MIB::acdDescTsFirstThres
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.1.1.12.1.3.1 snmpget -v2c -c public <target> ACD-DESC-MIB::acdDescTsFirstThres.1
Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-DESC-MIB::acdDescTsFirstThres OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.22420 | accedianMIB | ACCEDIAN-SMI |
| 1.3.6.1.4.1.22420.1 | acdProducts | ACCEDIAN-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.22420.1.1 | acdDesc | ACD-DESC-MIB |
| 1.3.6.1.4.1.22420.1.1.12 | acdDescTsTable | ACD-DESC-MIB |
| 1.3.6.1.4.1.22420.1.1.12.1 | acdDescTsEntry | ACD-DESC-MIB |
| 1.3.6.1.4.1.22420.1.1.12.1.3 | acdDescTsFirstThres | ACD-DESC-MIB |