ACD-DESC-MIB :: acdDescCpuUsageCurrent

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ACD-DESC-MIB › acdDescCpuUsageCurrent

acdDescCpuUsageCurrent

Module: ACD-DESC-MIB

OID (symbolic): ACD-DESC-MIB::acdDescCpuUsageCurrent

OID (numeric): 1.3.6.1.4.1.22420.1.1.20

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Indicates the current percentage of CPU usage.

What is acdDescCpuUsageCurrent?

This OID reports the current percentage of CPU being used right now, ranging from 0% to 100%. You monitor this in real-time to detect performance bottlenecks and decide if you need to reduce the load or upgrade the device. For example, a value of "85" means the CPU is currently 85% busy processing tasks.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.1.1.20
snmpwalk -v2c -c public <target> ACD-DESC-MIB::acdDescCpuUsageCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.1.1.20.1
snmpget -v2c -c public <target> ACD-DESC-MIB::acdDescCpuUsageCurrent.1

Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-DESC-MIB::acdDescCpuUsageCurrent OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.

How to Use in IPNetwork Monitor

Select an Accedian MetroNID device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type acdDescCpuUsageCurrent into the Find box to locate it in the OID tree, then select it and click OK. Indicates the current percentage of CPU usage. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22420accedianMIBACCEDIAN-SMI
1.3.6.1.4.1.22420.1acdProductsACCEDIAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.22420.1.1acdDescACD-DESC-MIB
1.3.6.1.4.1.22420.1.1.20acdDescCpuUsageCurrentACD-DESC-MIB