AC-PM-SYSTEM-MIB :: acPMNetConnectionStateChanges

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAC-PM-SYSTEM-MIBacPMNetConnectionStateChanges

acPMNetConnectionStateChanges

Module: AC-PM-SYSTEM-MIB

OID (symbolic): AC-PM-SYSTEM-MIB::acPMNetConnectionStateChanges

OID (numeric): 1.3.6.1.4.1.5003.10.11.2.21.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of times the state was toggled.

What is acPMNetConnectionStateChanges?

This counter increments each time a network connection transitions between active and inactive states. Rising values flag flaky connections or failover events that disrupt service continuity. A counter of 25 changes in an hour suggests the connection is unstable and needs investigation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5003.10.11.2.21.1.2
snmpwalk -v2c -c public <target> AC-PM-SYSTEM-MIB::acPMNetConnectionStateChanges

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5003.10.11.2.21.1.2.1
snmpget -v2c -c public <target> AC-PM-SYSTEM-MIB::acPMNetConnectionStateChanges.1

Start monitoring AudioCodes Mediant-series gateways/media servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AC-PM-SYSTEM-MIB::acPMNetConnectionStateChanges OID value, configure state conditions and alerts, and monitor any AudioCodes Mediant-series gateways/media servers from a single console.

How to Use in IPNetwork Monitor

Select an AudioCodes Mediant-series gateways/media server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type acPMNetConnectionStateChanges into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of times the state was toggled. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5003audioCodesAC-ATM-MIB
1.3.6.1.4.1.5003.10acPerformanceAUDIOCODES-TYPES-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5003.10.11acPMSystemAC-PM-SYSTEM-MIB
1.3.6.1.4.1.5003.10.11.2acPMSystemDataAC-PM-SYSTEM-MIB
1.3.6.1.4.1.5003.10.11.2.21acPMNetConnectionStateTableAC-PM-SYSTEM-MIB
1.3.6.1.4.1.5003.10.11.2.21.1acPMNetConnectionStateEntryAC-PM-SYSTEM-MIB
1.3.6.1.4.1.5003.10.11.2.21.1.2acPMNetConnectionStateChangesAC-PM-SYSTEM-MIB