A3COM-SWITCHING-SYSTEMS-MIB :: a3ComSysTokenRingPortACErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsA3COM-SWITCHING-SYSTEMS-MIBa3ComSysTokenRingPortACErrors

a3ComSysTokenRingPortACErrors

Module: A3COM-SWITCHING-SYSTEMS-MIB

OID (symbolic): A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysTokenRingPortACErrors

OID (numeric): 1.3.6.1.4.1.43.29.4.13.2.1.10

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.

What is a3ComSysTokenRingPortACErrors?

Counts protocol violations where stations fail to properly set Address Recognized (A) and Frame Copied (C) bits in frames. This indicates a misbehaving station that cannot process Standby Monitor Present frames correctly. Rising counts identify problematic devices that need isolation or replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.29.4.13.2.1.10
snmpwalk -v2c -c public <target> A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysTokenRingPortACErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.29.4.13.2.1.10.1
snmpget -v2c -c public <target> A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysTokenRingPortACErrors.1

Start monitoring 3Com SuperStack switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysTokenRingPortACErrors OID value, configure state conditions and alerts, and monitor any 3Com SuperStack switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-BRIDGE-R3-MIB
1.3.6.1.4.1.43.29switchingSystemsMibsA3COM-SWITCHING-SYSTEMS-BRIDGE-MIB
1.3.6.1.4.1.43.29.4a3ComSwitchingSystemsMibA3COM-SWITCHING-SYSTEMS-BRIDGE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.29.4.13a3ComSysTokenRingPortA3COM-SWITCHING-SYSTEMS-MIB
1.3.6.1.4.1.43.29.4.13.2a3ComSysTokenRingPortTableA3COM-SWITCHING-SYSTEMS-MIB
1.3.6.1.4.1.43.29.4.13.2.1a3ComSysTokenRingPortEntryA3COM-SWITCHING-SYSTEMS-MIB