ZTE-AN-OPTICAL-MODULE-MIB :: zxAnOptModuleIfShutdownUnplugEn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsZTE-AN-OPTICAL-MODULE-MIBzxAnOptModuleIfShutdownUnplugEn

zxAnOptModuleIfShutdownUnplugEn

Module: ZTE-AN-OPTICAL-MODULE-MIB

OID (symbolic): ZTE-AN-OPTICAL-MODULE-MIB::zxAnOptModuleIfShutdownUnplugEn

OID (numeric): 1.3.6.1.4.1.3902.1082.30.40.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates whether the zxAnOpticalModuleUnpluggedAlm should be generated when the port the optical module plugged in has been shutdown. enabled(1) : The zxAnOpticalOfflineTrapEnable indicates whether the zxAnOpticalModuleUnpluggedAlm should be generated or not. disabled(2): The zxAnOpticalModuleUnpluggedAlm should not be generated.

What is zxAnOptModuleIfShutdownUnplugEn?

This read-write value controls whether an unplugged-optical-module alarm can still be raised on a port that has been administratively shut down: enabled(1) means zxAnOpticalOfflineTrapEnable governs whether the alarm fires, disabled(2) (the default) suppresses it entirely. Admins leave this disabled to avoid alarm noise for optics on ports they've deliberately shut down for maintenance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.30.40.1.2
snmpwalk -v2c -c public <target> ZTE-AN-OPTICAL-MODULE-MIB::zxAnOptModuleIfShutdownUnplugEn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.30.40.1.2.1
snmpget -v2c -c public <target> ZTE-AN-OPTICAL-MODULE-MIB::zxAnOptModuleIfShutdownUnplugEn.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3902.1082.30.40.1.2.1 i <value>

Start monitoring ZTE access node (OLT/ONU with pluggable optical transceivers) (transceiver presence/DDM optical-power/temperature status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-OPTICAL-MODULE-MIB::zxAnOptModuleIfShutdownUnplugEn OID value, configure state conditions and alerts, and monitor any ZTE access node (OLT/ONU with pluggable optical transceivers) (transceiver presence/DDM optical-power/temperature status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteUAS-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.30zxAnInterfaceZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.30.40zxAnOpticalModuleMibZTE-AN-OPTICAL-MODULE-MIB
1.3.6.1.4.1.3902.1082.30.40.1zxAnOpticalModuleGlobalObjectsZTE-AN-OPTICAL-MODULE-MIB
1.3.6.1.4.1.3902.1082.30.40.1.2zxAnOptModuleIfShutdownUnplugEnZTE-AN-OPTICAL-MODULE-MIB