XSWITCH-MIB :: scGenGroupRspSwitchNotRespondingTimeout

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › XSWITCH-MIB › scGenGroupRspSwitchNotRespondingTimeout

scGenGroupRspSwitchNotRespondingTimeout

Module: XSWITCH-MIB

OID (symbolic): XSWITCH-MIB::scGenGroupRspSwitchNotRespondingTimeout

OID (numeric): 1.3.6.1.4.1.81.28.1.3.4.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Amount of time in which no hello-messages with acknowledge are received from the other switch, which cause the RSP to assume no connection to that switch, in 100mSec units.

What is scGenGroupRspSwitchNotRespondingTimeout?

The length of time, in 100ms units (default 5, i.e. 500ms), with no acknowledged hello messages from the peer switch before RSP assumes the link to that switch is down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.81.28.1.3.4.1.5
snmpwalk -v2c -c public <target> XSWITCH-MIB::scGenGroupRspSwitchNotRespondingTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.81.28.1.3.4.1.5.1
snmpget -v2c -c public <target> XSWITCH-MIB::scGenGroupRspSwitchNotRespondingTimeout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.81.28.1.3.4.1.5.1 i <value>

Start monitoring Modular switch platform with redundant management agents (agent-redundancy/RMON-style traffic-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XSWITCH-MIB::scGenGroupRspSwitchNotRespondingTimeout OID value, configure state conditions and alerts, and monitor any Modular switch platform with redundant management agents (agent-redundancy/RMON-style traffic-counter status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.81lannetGEN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.81.28switchChipXSWITCH-MIB
1.3.6.1.4.1.81.28.1scGenXSWITCH-MIB
1.3.6.1.4.1.81.28.1.3scGenGroupXSWITCH-MIB
1.3.6.1.4.1.81.28.1.3.4scGenGroupRspTableXSWITCH-MIB
1.3.6.1.4.1.81.28.1.3.4.1scGenGroupRspEntryXSWITCH-MIB
1.3.6.1.4.1.81.28.1.3.4.1.5scGenGroupRspSwitchNotRespondingTimeoutXSWITCH-MIB