All MIBs › XSWITCH-MIB › scEthPortMode
scEthPortMode
Module: XSWITCH-MIB
OID (symbolic): XSWITCH-MIB::scEthPortMode
OID (numeric): 1.3.6.1.4.1.81.28.2.1.1.1.28
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The flow control mode of the port when operated in full duplex: halfDuplex(1) - Half duplex connection, standard mode for segment fullDuplexNoPause(2) - Full duplex connection without exchanging flow control packets fullDuplexProprietaryFC(3) - Full duplex connection with Lucent's proprietary flow control frames exchanged fullDuplexISL(4) - Full duplex connection with ISL proprietary protocol control words for VLAN & priority exchanged, ISL = Inter-Switch-Link fullDuplexFlowControlISL(5) - Full duplex connection with both ISL proprietary protocol control words and flow control frames exchanged fullDuplexAsymTxPause(6) - Full duplex connection with STD 802.3x flow control frames sent from this port, but flow control packets received on it are not processed fullDuplexSymPause(7) - Full duplex connection with STD 802.3x flow control frames exchanged fullDuplexAsymRxPause(8) - Full duplex connection with no flow control frames sent from this port, but STD 802.3x flow control 0frames received on it are processed. For Giga ports, when auto-negotiation is enabled, the flow control mode is set internally according to auto-negotiation resolution; and access to this item is read-only.
What is scEthPortMode?
Selects the port's duplex and flow-control behavior: halfDuplex(1) for standard shared-segment operation, or one of several full-duplex variants that add Lucent proprietary flow control, ISL inter-switch-link tagging, or standard 802.3x pause frames in symmetric or asymmetric (Tx-only/Rx-only) form; on Gigabit ports with auto-negotiation enabled this becomes read-only since the mode is resolved automatically.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.81.28.2.1.1.1.28 snmpwalk -v2c -c public <target> XSWITCH-MIB::scEthPortMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.81.28.2.1.1.1.28.1 snmpget -v2c -c public <target> XSWITCH-MIB::scEthPortMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.81.28.2.1.1.1.28.1 i <value>
Start monitoring Modular switch platform with redundant management agents (agent-redundancy/RMON-style traffic-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XSWITCH-MIB::scEthPortMode OID value, configure state conditions and alerts, and monitor any Modular switch platform with redundant management agents (agent-redundancy/RMON-style traffic-counter status) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.81 | lannet | GEN-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.81.28 | switchChip | XSWITCH-MIB |
| 1.3.6.1.4.1.81.28.2 | scEth | XSWITCH-MIB |
| 1.3.6.1.4.1.81.28.2.1 | scEthPort | XSWITCH-MIB |
| 1.3.6.1.4.1.81.28.2.1.1 | scEthPortTable | XSWITCH-MIB |
| 1.3.6.1.4.1.81.28.2.1.1.1 | scEthPortEntry | XSWITCH-MIB |
| 1.3.6.1.4.1.81.28.2.1.1.1.28 | scEthPortMode | XSWITCH-MIB |