Wellfleet-CCT-NAME-MIB :: wfCircuitProtoMap

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-CCT-NAME-MIB › wfCircuitProtoMap

wfCircuitProtoMap

Module: Wellfleet-CCT-NAME-MIB

OID (symbolic): Wellfleet-CCT-NAME-MIB::wfCircuitProtoMap

OID (numeric): 1.3.6.1.4.1.18.3.3.2.3.1.5

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: CIRCUIT_PROTO_BRIDGE 1 CIRCUIT_PROTO_SPANTREE 2 CIRCUIT_PROTO_IP 3 CIRCUIT_PROTO_RIP 4 CIRCUIT_PROTO_EGP 5 CIRCUIT_PROTO_OSPF 6 CIRCUIT_PROTO_SNMP 7 CIRCUIT_PROTO_TFTP 8 CIRCUIT_PROTO_TCP 9 CIRCUIT_PROTO_DECNET4 10 CIRCUIT_PROTO_VINES 11 CIRCUIT_PROTO_SMDS 12 CIRCUIT_PROTO_FR 13 CIRCUIT_PROTO_IPX 14 CIRCUIT_PROTO_IPX_RIP 15 CIRCUIT_PROTO_XNS 16 CIRCUIT_PROTO_XNS_RIP 17 CIRCUIT_PROTO_AT 18 CIRCUIT_PROTO_SR 19 CIRCUIT_PROTO_FR_VC 20 CIRCUIT_PROTO_PRI_Q 21 CIRCUIT_PROTO_PPP 22 CIRCUIT_PROTO_OSI 23 CIRCUIT_PROTO_LLC2 24 CIRCUIT_PROTO_LNM 25 CIRCUIT_PROTO_X25 26 CIRCUIT_PROTO_ATM 27 CIRCUIT_PROTO_ATM_VC 28 CIRCUIT_PROTO_TELNET 29 CIRCUIT_PROTO_STA 30 CIRCUIT_PROTO_BGP 31 CIRCUIT_PROTO_DLS 32 CIRCUIT_PROTO_RARP 33 CIRCUIT_PROTO_BOOTP 34 CIRCUIT_PROTO_LLC2_VC 35 CIRCUIT_PROTO_AURP 36 CIRCUIT_PROTO_X25_VC 37 CIRCUIT_PROTO_DEMAND 38 CIRCUIT_PROTO_CL_IP 39 CIRCUIT_PROTO_PROXY 40 CIRCUIT_PROTO_TELNET_CLIENT 41 CIRCUIT_PROTO_SW_LAPB 42 CIRCUIT_PROTO_SR_SPANTREE 43 CIRCUIT_PROTO_NML 44 CIRCUIT_PROTO_RDISC 45 CIRCUIT_PROTO_SDLC 46 CIRCUIT_PROTO_NBASE 47 CIRCUIT_PROTO_SWSMDS 48 CIRCUIT_PROTO_FRSW_CONG 49 CIRCUIT_PROTO_SW_PROXY 50 CIRCUIT_PROTO_FRSW 51 CIRCUIT_PROTO_APPN 52 CIRCUIT_PROTO_APPN_CP 53 CIRCUIT_PROTO_ISDN 54 CIRCUIT_PROTO_LINEMANAGER 55 CIRCUIT_PROTO_ATM_UNI 56 CIRCUIT_PROTO_ATM_UNI_VCL 57 CIRCUIT_PROTO_IGMP 58 CIRCUIT_PROTO_DVMRP 59 CIRCUIT_PROTO_NBIP 60 CIRCUIT_PROTO_FTP 61 CIRCUIT_PROTO_WCP 62 CIRCUIT_PROTO_ARP 63 CIRCUIT_PROTO_ST2 64 CIRCUIT_PROTO_ATMZ 65 CIRCUIT_PROTO_ATM_LE 66 CIRCUIT_PROTO_IPEX 67 CIRCUIT_PROTO_NLSP 68 CIRCUIT_PROTO_BGPRS 69 CIRCUIT_PROTO_CRM 70 CIRCUIT_PROTO_RR 71 CIRCUIT_PROTO_NPT 72 CIRCUIT_PROTO_ATM_SIG 73 CIRCUIT_PROTO_BOT 74 CIRCUIT_PROTO_PIM 75 CIRCUIT_PROTO_NTP 76 CIRCUIT_PROTO_MIP 77 CIRCUIT_PROTO_BNX_RSVD_78 78 CIRCUIT_PROTO_BNX_RSVD_79 79 CIRCUIT_PROTO_ISDB 80 CIRCUIT_PROTO_FWALL 81 CIRCUIT_PROTO_WEP 82 CIRCUIT_PROTO_BACP 83 CIRCUIT_PROTO_RADIUS 84 CIRCUIT_PROTO_IPV6 85 CIRCUIT_PROTO_RIP6 86 CIRCUIT_PROTO_AOT 87 CIRCUIT_PROTO_RSVP 88 CIRCUIT_PROTO_MOSPF 89 CIRCUIT_PROTO_PORTMTX 90 CIRCUIT_PROTO_CONVSTR 91 CIRCUIT_PROTO_RCMDS 92 CIRCUIT_PROTO_DNS 93 CIRCUIT_PROTO_COLUMBO 94 CIRCUIT_PROTO_NAT 95 CIRCUIT_PROTO_ASR 96 CIRCUIT_PROTO_NHRP 97 CIRCUIT_PROTO_AHB 98 CIRCUIT_PROTO_HTTP 99 CIRCUIT_PROTO_FRPT 100 CIRCUIT_PROTO_FRSVC 101 CIRCUIT_PROTO_STACLZS 102 CIRCUIT_PROTO_L2TP 103 CIRCUIT_PROTO_BNX_RSVD_104 104 CIRCUIT_PROTO_VCCT 105 CIRCUIT_PROTO_TAG1Q 106 CIRCUIT_PROTO_TARP 107 CIRCUIT_PROTO_MPS 108 CIRCUIT_PROTO_DHCP 109 CIRCUIT_PROTO_CAPI 110 CIRCUIT_PROTO_IPSEC 111 CIRCUIT_PROTO_MPLS_LDP 112 CIRCUIT_PROTO_MPLS_MLM 113 CIRCUIT_PROTO_IISIS 114 CIRCUIT_PROTO_COPS 115 CIRCUIT_PROTO_DIFFSERV 116 CIRCUIT_PROTO_IKE 117 CIRCUIT_PROTO_VRRP 118 CIRCUIT_PROTO_WIREDUND 119 CIRCUIT_PROTO_MLT 120 CIRCUIT_PROTO_L2TP_CLIENT 121 CIRCUIT_PROTO_DSQMS 122 NUMBER_OF_PROTOCOLS 122

What is wfCircuitProtoMap?

This read-write OCTET STRING object is a bitmask indicating which of over a hundred defined protocols (such as CIRCUIT_PROTO_IP, CIRCUIT_PROTO_PPP, CIRCUIT_PROTO_OSPF) are enabled on this circuit, with each bit number in the DESCRIPTION corresponding to a specific protocol. Admins read or set this bitmask to see or control which protocol stacks are active on a given circuit. Setting the bit corresponding to CIRCUIT_PROTO_IP (3) enables IP protocol processing on that circuit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.3.2.3.1.5
snmpwalk -v2c -c public <target> Wellfleet-CCT-NAME-MIB::wfCircuitProtoMap

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.3.2.3.1.5.1
snmpget -v2c -c public <target> Wellfleet-CCT-NAME-MIB::wfCircuitProtoMap.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.3.2.3.1.5.1 s <value>

Start monitoring Wellfleet/Bay Networks multiprotocol router (circuit-name assignment/inventory status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCT-NAME-MIB::wfCircuitProtoMap OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol router (circuit-name assignment/inventory status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.3wfSystemWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.3.2wfServicesWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.3.2.3wfCircuitNameTableWellfleet-CCT-NAME-MIB
1.3.6.1.4.1.18.3.3.2.3.1wfCircuitNameEntryWellfleet-CCT-NAME-MIB
1.3.6.1.4.1.18.3.3.2.3.1.5wfCircuitProtoMapWellfleet-CCT-NAME-MIB