WIENER-CRATE-MIB :: sysFactoryDefaults

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › sysFactoryDefaults

sysFactoryDefaults

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::sysFactoryDefaults

OID (numeric): 1.3.6.1.4.1.19947.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A set operation performs a complete factory reset of ALL data stored in the controller (e.g. community names, passwords, ...).

What is sysFactoryDefaults?

Setting this performs a complete factory reset of everything stored on the controller, including SNMP community strings and passwords, per the source description -- an admin should treat this as a destructive, no-undo operation before writing to it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.1.5
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::sysFactoryDefaults

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.1.5.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::sysFactoryDefaults.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.1.5.1 i <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::sysFactoryDefaults OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.1systemWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.1.5sysFactoryDefaultsWIENER-CRATE-MIB