WIENER-CRATE-MIB :: outputVoltageFallRate

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › outputVoltageFallRate

outputVoltageFallRate

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::outputVoltageFallRate

OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.14

Node type: OBJECT-TYPE

Type: Float

Access: read-write

Description: Voltage Rise Slew Rate [V/s]. The slew rate of the output voltage if it decreases (after switch off or if the Voltage has been changed).

What is outputVoltageFallRate?

The slew rate (in V/s) at which this channel's output voltage is allowed to decrease, e.g. at switch-off or when the setpoint is lowered; note the source MIB's own description text opens with the mislabeled phrase 'Voltage Rise Slew Rate' even though its explanation and the object's own name both describe the falling case, an apparent copy-paste artifact in the vendor text.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.14
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputVoltageFallRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.14.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputVoltageFallRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.14.1 s <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputVoltageFallRate OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.14outputVoltageFallRateWIENER-CRATE-MIB