Description: Definition of user-changeable items. A bit field packed into an integer which define the behavior of the output channel. Usable for WIENER LV devices only. The position of the bit fields in the integer value are: Bit 0: Voltage ramping at switch off: 0: Ramp down at switch off. 1: No ramp at switch off (immediate off) Bit 1, 2: Set different regulation modes, dependent on the cable inductance: 0: fast: short cables, up to 1 meter. 1: moderate: cables from 1 to 30 meter. 2: fast: identical to 0 (should not be used) 3: slow: cables longer than 30 meter. Bit 3: Internal sense line connection to the output (MPOD only): 0: The sense input at the sense connector is used for regulation. 1: The output voltage is used for regulation. Any signals at the sense connector are ignored. Bit 4: Enable External Inhibit input. 0: The external inhibit input is ignored. 1: The external inhibit input must be connected to a voltage source to allow switch on. Bit 5: Disable Global Inhibit inputs. 0: The global inhibit/interlock inputs of the system is active. 1: The global inhibit/interlock inputs of the system is ignored. Bit 6: Automatic Power On. 0: After switching the main system switch ON, the output is not switched on automatically. A separate outputSwitch command is required. 1: After switching the main system switch ON, the output is switched on automatically. If 'Disable Global Inhibit' (bit 5) is set, the output will be switched on regardless of the global inhibit/interlock signals. Community required for write access: guru.
What is outputUserConfig?
A packed bitfield of user-changeable behavior flags for this channel (WIENER LV devices only per the source description), e.g. bit 0 controls whether the channel ramps down or switches off immediately, and bits 1-2 select a regulation mode tuned to the connected cable's inductance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.37 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputUserConfig
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.37.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputUserConfig.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.37.1 i <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputUserConfig OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.37 | outputUserConfig | WIENER-CRATE-MIB |