All MIBs › WIENER-CRATE-MIB › outputTripTimeMaxTemperature
outputTripTimeMaxTemperature
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputTripTimeMaxTemperature
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.44
Node type: OBJECT-TYPE
Type: OutputTripTime
Access: read-write
Description: Minimum time the outputSupervisionMaxTemperature threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxTemperature.
What is outputTripTimeMaxTemperature?
Minimum time (in ms) the outputSupervisionMaxTemperature threshold must stay violated before the configured trip action fires.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.44 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputTripTimeMaxTemperature
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.44.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputTripTimeMaxTemperature.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.44.1 s <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputTripTimeMaxTemperature OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.44 | outputTripTimeMaxTemperature | WIENER-CRATE-MIB |