All MIBs › WIENER-CRATE-MIB › outputTripTimeMaxSenseVoltage
outputTripTimeMaxSenseVoltage
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputTripTimeMaxSenseVoltage
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.42
Node type: OBJECT-TYPE
Type: OutputTripTime
Access: read-write
Description: Minimum time the outputSupervisionMaxSenseVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxSenseVoltage.
What is outputTripTimeMaxSenseVoltage?
Minimum time (in ms) the outputSupervisionMaxSenseVoltage threshold must stay violated before the configured trip action fires.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.42 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputTripTimeMaxSenseVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.42.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputTripTimeMaxSenseVoltage.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.42.1 s <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputTripTimeMaxSenseVoltage OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.42 | outputTripTimeMaxSenseVoltage | WIENER-CRATE-MIB |