WIENER-CRATE-MIB :: outputTripActionMinSenseVoltage

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › outputTripActionMinSenseVoltage

outputTripActionMinSenseVoltage

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::outputTripActionMinSenseVoltage

OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.47

Node type: OBJECT-TYPE

Type: OutputTripAction

Access: read-write

Description: Trip action if outputSuperisionMinSenseVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 0..1 of outputSupervisionBehavior.

What is outputTripActionMinSenseVoltage?

Configures what happens when the min-sense-voltage supervision limit is violated: on WIENER LV devices, options range from ignoring the failure up to shutting off the whole crate; on iseg HV devices the options instead range through ramping the channel down or an emergency-off up to shutting off the whole board, per the source description.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.47
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputTripActionMinSenseVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.47.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputTripActionMinSenseVoltage.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.47.1 s <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputTripActionMinSenseVoltage OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.47outputTripActionMinSenseVoltageWIENER-CRATE-MIB