All MIBs › WIENER-CRATE-MIB › outputSupervisionMaxTemperature
outputSupervisionMaxTemperature
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputSupervisionMaxTemperature
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.20
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: If the measured module temperature is above this value, the power supply performs the function defined by SupervisionAction.
What is outputSupervisionMaxTemperature?
Upper module-temperature limit for this channel; exceeding it triggers the configured supervision action to prevent thermal damage.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.20 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxTemperature
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.20.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxTemperature.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.20.1 i <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputSupervisionMaxTemperature OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.20 | outputSupervisionMaxTemperature | WIENER-CRATE-MIB |