WIENER-CRATE-MIB :: outputSupervisionMaxTemperature

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › WIENER-CRATE-MIB › outputSupervisionMaxTemperature

outputSupervisionMaxTemperature

Module: WIENER-CRATE-MIB

OID (symbolic): WIENER-CRATE-MIB::outputSupervisionMaxTemperature

OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.20

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: If the measured module temperature is above this value, the power supply performs the function defined by SupervisionAction.

What is outputSupervisionMaxTemperature?

Upper module-temperature limit for this channel; exceeding it triggers the configured supervision action to prevent thermal damage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.20
snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.20.1
snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxTemperature.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.20.1 i <value>

Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputSupervisionMaxTemperature OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19947wienerWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1crateWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3outputWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2outputTableWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1outputEntryWIENER-CRATE-MIB
1.3.6.1.4.1.19947.1.3.2.1.20outputSupervisionMaxTemperatureWIENER-CRATE-MIB