All MIBs › WIENER-CRATE-MIB › outputSupervisionMaxPower
outputSupervisionMaxPower
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputSupervisionMaxPower
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.24
Node type: OBJECT-TYPE
Type: Float
Access: read-write
Description: If the measured power (measured current * measured terminal voltage) is above this value, the power supply performs the function defined by SupervisionAction.
What is outputSupervisionMaxPower?
Upper power limit (current times terminal voltage) for this channel; exceeding it triggers the configured supervision action, catching an over-power condition that a voltage or current limit alone might miss.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.24 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.24.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionMaxPower.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.24.1 s <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> outputSupervisionMaxPower.1
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputSupervisionMaxPower OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.24 | outputSupervisionMaxPower | WIENER-CRATE-MIB |