outputSupervisionBehavior
Module: WIENER-CRATE-MIB
OID (symbolic): WIENER-CRATE-MIB::outputSupervisionBehavior
OID (numeric): 1.3.6.1.4.1.19947.1.3.2.1.15
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: A bit field packed into an integer which define the behavior of the output channel / power supply after failures. For each supervision value, a two-bit field exists. The enumeration of this value (..L+..H*2) is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate. iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. The position of the bit fields in the integer value are: Bit 0, 1: outputFailureMinSenseVoltage Bit 2, 3: outputFailureMaxSenseVoltage Bit 4, 5: outputFailureMaxTerminalVoltage Bit 6, 7: outputFailureMaxCurrent Bit 8, 9: outputFailureMaxTemperature Bit 10, 11: outputFailureMaxPower Bit 12, 13: outputFailureInhibit Bit 14, 15: outputFailureTimeout
What is outputSupervisionBehavior?
A packed bitfield configuring what this channel does when each supervision limit (voltage, current, temperature, etc.) is violated -- e.g. ignore the failure, shut off just this channel, shut off its whole group, or shut off the entire crate -- letting an admin tune failure response per channel.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.15 snmpwalk -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionBehavior
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.19947.1.3.2.1.15.1 snmpget -v2c -c public <target> WIENER-CRATE-MIB::outputSupervisionBehavior.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.19947.1.3.2.1.15.1 i <value>
Start monitoring W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WIENER-CRATE-MIB::outputSupervisionBehavior OID value, configure state conditions and alerts, and monitor any W-IE-NE-R VME/NIM crate power supply mainframe (channel voltage/current/temperature/fault status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.19947 | wiener | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1 | crate | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3 | output | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2 | outputTable | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1 | outputEntry | WIENER-CRATE-MIB |
| 1.3.6.1.4.1.19947.1.3.2.1.15 | outputSupervisionBehavior | WIENER-CRATE-MIB |